Description
The product functions are primarily classified into two categories: temperature function and humidity function;
The temperature function is as follows:
1. Automatic identification of the operating mode:
The system automatically recognizes the operating mode based on the start/stop temperature;
Start temperature > stop temperature, cooling mode 'C'; start temperature < stop temperature, heating mode 'H';
2. Cooling Mode:
When the detected temperature is greater than or equal to the starting temperature, the relay is activated, the red indicator light illuminates, and the refrigeration unit begins to operate;
When the detected temperature is less than or equal to the shutdown temperature, the relay is deactivated, the red indicator light turns off, and the refrigeration unit stops operating;
3. Heating Mode:
When the detected temperature is less than or equal to the starting temperature, the relay is activated, the red indicator light illuminates, and the heating equipment begins to operate;
When the detected temperature is greater than or equal to the stopping temperature, the relay is deactivated, the red indicator light turns off, and the heating equipment stops operating.
4. OFE Temperature Correction Function (-10.0 ~ 10.0℃):
The system operates for extended periods, and deviations may occur. This correction function ensures that the actual temperature is equal to the measured temperature plus the calibration value;
How to set the start/stop temperature:
1. On the running interface, press and hold the "TM+" button for more than 3 seconds to access the start temperature setting interface. The test can modify the settings using the TM+ and TM- buttons. Once the settings have been modified, wait 6 seconds for the test to automatically exit and save;
2. On the running interface, press and hold the "TM-" button for more than 3 seconds to access the stop temperature setting interface. The test can modify the settings using the TM+ and TM- buttons. Once the settings have been modified, wait 6 seconds for the test to automatically exit and save;
The humidity functions are as follows:
1. Automatic operating mode identification:
The system automatically recognizes the operating mode based on the start-up humidity/shut-down temperature;
Start humidity > stop humidity, dehumidification mode "d"; start humidity < stop humidity, humidification mode "E";
2. Dehumidification Mode:
When the detected humidity is greater than or equal to the start humidity level, the relay is activated, the green indicator light illuminates, and the dehumidification unit begins operating;
When the detected humidity is less than or equal to the stop humidity level, the relay is deactivated, the green indicator light is off, and the dehumidification unit stops operating;
3. Humidification Mode:
When the detected humidity is less than or equal to the starting humidity, the relay is activated, the green indicator light illuminates, and the humidification device begins to operate;
When the detected humidity is greater than or equal to the starting humidity, the relay is deactivated, the green indicator light turns off, and the humidification device stops operating.
4. RH Humidity Correction Function (-10.0 ~ 10.0 ℃):
The system operates for an extended period, and deviations may occur. Thanks to this function correction, the humidity reading is calculated as: measured humidity + calibration value;
How to adjust the start/stop humidity:
1. On the running interface, press and hold the "RH+" button for more than 3 seconds to access the start humidity setting interface. The test can modify the parameters by pressing the RH+ and RH- buttons. Once the parameter adjustment is complete, wait 6 seconds for the system to automatically exit and save;
2. On the running interface, press and hold the "RH-" button for more than 3 seconds to access the stop humidity setting interface. The test can modify the parameters by pressing the RH+ and RH- buttons. Once you have finished changing the settings, wait 6 seconds for the process to automatically exit and save.
Features