12V/24V Platinum Time Delay Relay Module, Trigger Cycle Delay, Dual MOSFET, Flow Control
Buying for your business?
Negotiated prices excl. VAT up to -20%
Product information
Description
Specifications:
Item Type: PCB Time Delay Switch Material: PCB Size: PCB approximately 60 x 34 mm / 2.4 x 1.3 inches
Note: The module has an active output; the output voltage is equal to the input voltage. The input voltage is high (5~36V), making it compatible with most devices and very convenient. It features an emergency stop function (stop button). Reverse polarity protection prevents the product from burning out. You can set various OP, CL, and LOP parameters. These parameters are independent and are saved automatically. All settings are retained after closing the form.
Operating Principle: P1: Trigger signal; the relay is in "OP" mode and then disconnected. The "OP" time is as follows: P1.1: The signal is reactivated and is invalid.
P1.2: The signal is reactivated and the clock restarts. P1.3: The signal is reactivated, the relay closes and the clock stops. P-2: Trigger signal, the relay is closed during time "CL", the relay is closed during time "OP", then the relay disconnects. P3.1: Trigger signal, the relay starts after time "OP", the relay closes during time "CL", then completes one cycle. When the trigger signal is active, the relay is closed and the clock is stopped. You can set the number of cycles ("LOP"). P3.2: No trigger signal, the relay enters time "OP", the relay closes during time "CL", the cycle is in use. You can set the cycle frequency ("LOP"). P-4: Signal function. When the trigger signal synchronization is canceled, the relay remains activated. When the signal disappears, the relay is in "OP" after the synchronization time. If there are other signals during the synchronization process, the timing is clear.Package Contents:
1 Relay Module
1. The time delay relay module is equipped with an optocoupler and isolation, improved anti-interference capability, and an industrial-grade printed circuit board. The conduction and cutting process produces no noise, sparks, or electromagnetic interference.
2. Increased pause mode. When activated, no operation will be performed for 5 minutes. Then, the monitor will automatically turn off. Each key can be activated.
3. Parameters - Operating Voltage: 5V-36V; Quiescent Current: 20mA; Working Current: 50mA; Operating Temperature: -40-85°C; Output power: DC 5V-36V, at room temperature, DC 15A, 400W power! Improved heat dissipation conditions; maximum current reaches 30A.
4. Trigger signal - (3.0V-24V) with optocoupler isolation can improve the system's anti-interference capability (customers can also short the public ground).
5. Note: 2. 'DC+' and 'charge+' are internal short circuits of the magnetic poles, but 'DC-' and 'charge-' cannot be short-circuited during use; otherwise, the load cannot be switched, and the corresponding load will carry current.
Features
- BrandOTHERS
- ManoMano ReferenceME223249094
- MMID420913431885