1pc Industrial Grade RS485 Signal Repeater Amplifier Isolated Distance Extender

£18.99
Sold by STUNACY

You may also like

Compare with similar items

Product information

Description

1、Industrial grade design, communication is completely isolated, stable and reliable performance, transmission rate is up to 500Kbps

2、Built-in high-quality DC/DC isolated power supply module realizes electrical isolation between ports

3、Support multi-machine communication, can connect up to 128 nodes, and transmission distance is up to 1200 meters

4、Data flow automatic control technology, automatically distinguish and control data transmission direction

5、Multiple protective measures: positive and negative 15KV ESD protection; 600W dual channel TVS protection; 2.5KV communication isolation

Description: This isolated RS485E repeater is a kind of high-performance

industrial grade RS485 signal amplifier and extender. It can automatically

sense data flow direction and communication baud rate, not requiring any

control or handshaking signals, and ensuretransparent data

transmission. Equipment power supply and communication signal are

completely isolated, withsurge protection and static

protection. It features long distance transmission, high speed, stable and

reliable performance. Widely used for attendance machine, IC card charging

system, automation control, access control system, parking lot, dining service

system,highway toll system. Features:

Industrial grade design, communication is

completely isolated, stable and reliable performance, transmission rate is up

to 500Kbps.

Built-in high-quality DC/DC isolated power

supply module realizes electrical isolation between ports.

Support multi-machine communication, can

connect up to 128 nodes, and transmission distance is up to 1200 meters.

Data flow automatic control technology,

automatically distinguish and control data transmission direction.

Multiple protective measures: positive and

negative 15KV ESD protection; 600W dual channel TVS protection; 2.5KV

communication isolation.

Wide range of power supply from 9V to 36VDC,

and support reverse polarity protection.

Specifications:

Recommended Value (Typical)

Limit Value

Working Voltage

9V~36V DC

9V~36V DC

Rated Power

0.36W (9V/35mA; 12V/27mA; 24V/15mA)

0.5W

Working Temperature

-30℃~70℃

-40℃~80℃

Responsible for Capacity

1~128 node

128 node

Communication Distance

0~1200 meters

1200 meters

Communication Rate

300~500K bps

500Kbps

Note: It is suggested to use RS485E equipment under

recommended value for long-term stable operation. Equipment will not damage

when working under limit value, but may result in performance degradation. Do

not exceed the limit value, otherwise it may damage the equipment. Wiring Note: 1. 485 communication wires must be shielded

twisted pair. It is better to have multi-strand for spare, and the total length

is not more than 1,200 meters. 2. Wires should be as far as possible away

from high-voltage wires, do not parallel with the power cord and cannot be

bundled together. 3.485 bus must

behand-hand

bus structure, and must not be star connection and fork connection. 4. 485 repeater must be used when there is

more than 30 controllers or wire is longer than 500 meters. 5. AC power supply equipment and case must

be grounded well. 6. Connect GND of all 485 devices with

shielded cable. 7. Connect 120 ohm terminal resistor in parallel

to 485+(A) and 485-(B) of the last 485 device. RS-485 bus wire should be 2-core shielded

twisted pair copper wire, of diameter 0.5 to 0.75 square millimeters, impedance

38 to 88 ohms / km, capacity of 30 to 50 nanofarad / km, twist pitch is 20mm

(if wire distance is not more than 500 meters, the standard can be appropriately

lower, but must be twisted pair) Bus Limit: Consists of two or more devices with

physical connections between each other, the bus can be connected up to 128

devices, in the case of no repeater, the bus length is not more than 1200

meters. The system bus should not branch, and if branch is unavoidable, the

following requirements must be met: 1. Length of branch is not more than 10

meters; the sum of bus length in not more than 800 meters; the total quantity

of equipment on the branch is not more than 50. 2. All communication signal wires should be

as far as possible away from interference source, the signal line should go

weak wells, and cannot be in parallel with strong power (such as 220 volt

residential power) or RF signal wire (such as CATV, large signal audio cable).

If in parallel, the distance should be longer than 0.5 meters. 3. All wire contacts must be welded or

screwed to the connection, and do waterproof and moisture-proof treatment. Signal Common Ground: 1. All devices on the same network segment

must have a uniform signal ground to avoid common mode interference. 2. When using centralized power supply, connect

DC negative poles of all power (including the communication device power) of

the same network segment together directly to form a common signal ground. At

this time the signal ground is the DC power ground. 3. When using individual power supply, connect

the ground (black wire) pins of all the bus devices on the same network segment

together to form a common signal ground. Indicator Light: PWR: Green power supply indicator light, normally

on when power on. COM: Red data indicator light, flashes when

there is data on bus. Terminal Definition: DC9V: power supply G: Isolate RS-485 ground, can connect to

earth or shielded wire A: RS-485 signal input/output positive B: RS-485 signal input/output negative Recommended Debug Methods: Make sure the wiring is correct. 1, Common ground: use 1 wire or shield wire

to connect GND of all 485 devices together, which can avoid potential

difference that influence communication between all devices. 2, Terminal resistor: connect a 120ohm

terminal resistor in parallel to 485+ and 485- of the last 485 device, in order

to improve communication quality. 3, Disconnect middle section: by disconnecting

in the middle to check if it is because there are too many loads, or

communication distance is too long, or some device is damaged that influence

the whole communication wire. 4, Single wire: connect one single wire to

device, which can be used to eliminate if the wiring causes communication

fault. 5, Change convertor: change convertor to eliminate

if the convertor quality influences communication quality. 6, Laptop debug: make sure your laptop

communicates normally, replay client's computer to communicate.

Package Includes: 1 x RS-485 Repeater

Note:

Please note that the new type and old type of this product will be sent randomly, and make sure you will not mind before ordering.

Features

  • Brand
    STUNACY
  • ManoMano Reference
    ME215566672
  • MMID
    772204579158
  • Product code
    STYM0512-GS02666
  • EAN
    4970488583233
You are here:
The DIY, home and garden specialist

The DIY, home and garden specialist

Reliable delivery

Reliable delivery

Payment in 3x or up to 30 days free of charge

Payment in 3x or up to 30 days free of charge

More than 7 million individual and professional customers

More than 7 million individual and professional customers