1pc K24 Turbine Digital Diesel Oil Fuel Flow Meter Gauge For Chemicals Liquid Water
You may also like
Compare with similar items
Product information
Description
1、This chemical flow meter control panel adopts modular design
2、It is fully functional, convenient to operate and has simple structure
3、Large LCD display is convenient for clear reading
4、It can be used to meter methanol, kerosene, diesel, fuel, urea water
5、Widely used in petroleum, chemical industry, medicine, transportation, food industry and business field
Features:
This chemical flow meter control panel adopts modular design.
It is fully functional, convenient to operate and has simple structure.
Large LCD display is convenient for clearreading.
It can be used to meter methanol, kerosene, diesel, fuel, urea water.
Widely used in petroleum, chemical industry, medicine, transportation, food industry and business field.
Specifications: Model: K24 Fluid:Methanol, diesel, fuel, kerosene, urea water Inlet/Outlet Thread: G1 (BSPP)Measurement Accuracy:±1%Repeatability:±0.5%
Maximum Pressure: 5BAR Working Voltage:2.3-3.3V Standby Time: 2 yearsFlow Range:10-90L/MIN Single Count: 0.00-9999.9
Total Count: 0.00-999999.9 Instruction: 1. Measuring Unit SettingUnder
standby state or current amount display state, press and hold
MENU+RESET buttons for 5 seconds to enter unit conversion setting, then
press RESET button to select unit in turn of LTR - GAL - PT - QT - LTR.
Press and hold MENU button for 3 seconds to exit unit conversion
setting.2. Accumulative and Current Amount ResetPress and hold
RESET button and LCD screen displays on full screen, wait till the full
screen display end then loose the RESET button. At this time the
accumulative amount and current amount is reset.3. Error Coefficient and Accumulative Amount InquireUnder
standby state, press MENU + RESET button together, then LCD display
shows the error coefficient on the upper row, and accumulative amount on
the lower row.4. Error Coefficient CalibrationUnder standby
state or current amount display state, press and hold MENU button for 3
seconds to enter error coefficient calibration mode. The first digit
flashes, press MENU button to change position of the digit, and press
RESET button to change digit. As this coefficient increases, output oil
quantity reduces. Then press and hold MENU button for 3 seconds to end
error coefficient calibration and return to current amount display
state, and the current amount is reset as zero. The calibration error
coefficient range is 0.1000 to 9.9999. For example, original coefficient
is 1.000, when it displays 100 liters output of oil, the actual oil
output is 100 liters. If you need 2 liter reduced, set the coefficient
as 1.020, then the output would be 98 liters.5. MaintenanceWhen
battery voltage is too low, a battery symbol appears on the LCD
display, which reminds user to replace battery. Too short battery life
can cause damage to the meter because of battery leakage. This meter has
designed standby life of about two years, but we suggest customer to
replace a battery each year, and check battery electrodes if there is
any rust. Battery should be removed if not using flow meter during long
time. Package Includes: 1 xTurbine Flow Meter