Skip to main content
1/5

5V 12V 24V Time Delay Relay Module, 0.01s-9999min Stop Cycle Timer with LCD Display

£23.11
Of which environmental contribution £0.01 including VAT.

Buying for your business?

Negotiated prices excl. VAT up to -20%

Sold by MICHH-GB

Product information

Description

Features:

1. With an LCD display, the current mode and settings are clear at a glance. 2. Supports high or low level triggering and switching quantity control, suitable for most applications. 3. Wide power supply voltage range of 6~30V, supports 5.0V micro USB power supply, very convenient to use. 4. Supports UART data download and parameter setting. 5. One-button emergency stop function (STOP button) with reverse connection protection.

Specifications:

Features: 1. With an LCD display, the current mode and settings are clear at a glance. 2. Supports high or low level triggering and switching quantity control, suitable for most applications.

3. Wide 6~30V power supply voltage, supports 5.0V micro USB power, very convenient to use. 4. Supports UART data download and parameter setting. 5. One-button emergency stop function (STOP button), with reverse connection protection. 6. Added sleep mode: after activation, if no operation is performed within 5 minutes, the LCD backlight automatically turns off, and all buttons wake the screen. 7. Different parameters (0P, CL, LOP) can be set; these parameters are independent of each other and saved separately. 8. Automatically saves all settings in case of power failure. 9. Industrial-grade printed circuit board with optocoupler isolation to improve anti-interference capability.

Specification: Item Type: Delay Relay Module Operating Voltage: 6-30V Timing Range: 0.01s - 9999min continuously adjustable Trigger Signal Source: High-level trigger (3.0V~24V), low-level trigger (0.0V~0.2V), switching quantity control (passive switch) Output Capacity: Can control devices up to 30V 5A or up to 220V 5A Quiescent Current: 15mA Operating Current: 50mA Lifespan: >100,000 cycles Operating Temperature: -40~85°C Size: 88 x 3.8 x 1.9cm / 3.15x1.5x0.75in

How to Choose the Range Timing: In the OP/CL parameter modification interface, briefly press the STOP button to select the timing range: XXXX: timing range is 1s~9999s XXX.X: time range is 0.1s to 999.9s XX.XX: time range is 0.01s to 99.99s XXXX: time range is 1min to 9999min

Parameter Setting: Parameter description: OP: conduction time, CL: disconnection time, LOP: cycle number (1-9999 times, ''----'' means infinite loop) a) Enter the setting interface by pressing and holding the SET button; b) First, set the operating mode; the operating mode will flash. Set the operating mode by briefly pressing the UP/DOWN button; c) Briefly press the SET button to select the operating mode and enter the system parameter settings; d) In the system parameter setting interface, briefly press the SET button to change the system parameters to be modified, then briefly press/long press the UP/DOWN button to modify them; (Note: Briefly press SET in modes P-1 ~ P-3, P-7); e) In the OP/CL parameter modification interface, press STOP to change the timing unit (1 s/0.1 s/0.01 s/1 min); f) Once all parameters are set, press and hold the SET button to save the settings and exit the setting interface;

Operating mode description: P1: After the signal is triggered, the relay turns on for the OP time, then turns off; during the OP time, the signal is triggered again. P2: After the signal is triggered, the relay turns on for the OP time, then turns off; During OP time, the signal triggers the P3 recount: after the signal is triggered, the relay activates during OP time and then deactivates; during OP time, the signal triggers the reset again, the relay is disconnected, and the timing is stopped. P4: after the trigger signal is given, the relay activates during OP time, then deactivates, and deactivates once the timing is complete; P5: give the trigger signal, once the relay activates during OP time, the relay deactivates during CL time, then loops the above action, the signal is given again within the cycle, the relay is disconnected, and the timing is stopped; the number of cycles (LOP) can be set; P6: no trigger signal is required after power-up, the relay activates during OP time, deactivates during CL time, and the above action is cycled; the number of cycles (LOP) can be set. P7: Signal Maintenance Function If there is a trigger signal, the timing is cleared, the relay remains on; when the signal disappears, the relay is deactivated after the OP delay; during timing, if there is a signal, the timing is cleared;

Additional Function: a) Auto Standby Function: In the operating interface, press or hold the STOP button to activate or deactivate the auto standby function (LP select on to start the standby function, off to deactivate the standby function); b) Relay Function Selection: In the operating interface, the relay function is activated or deactivated by briefly pressing the STOP button; 'on' corresponds to the conduction condition, the relay is normally on, and 'off' corresponds to the conduction condition, and the relay is not on; 'off' in the 'out' state, the system flashes 'OUT'; c) Parameter view: In the running interface, briefly press the SET button to display the current system parameters. This does not affect the normal operation of the system. d) Switching display content: In P-5 and P-6 modes, change the display content (running time/cycle number) by briefly pressing the DOWN button. Package list: 1 x Delay Relay Module

Features

  • Brand
    OTHERS
  • Power source
    Corded
  • Material
    Plastic
  • Display type
    Digital thermometer
  • Contact type
    Normally open
  • ManoMano Reference
    ME223250324
  • MMID
    336015300005
  • Product code
    Krlin-45665