Features:

1. This temperature controller is equipped with a high-precision sensor, providing accurate measurement data and stable performance.
2. The ABS flame-retardant casing design is adopted for this incubator temperature controller, making it safer and more reliable.
3. It is suitable for incubators, home refrigerators, home water heaters, greenhouse cultivation, and supermarket freezing equipment.
4. This incubator temperature controller is not only small in size but also easy to use and adjust in stages.
5. The measurement accuracy of 0.3°C and the temperature measurement range of -40 to 110°C distinguish this temperature controller.


Specifications:

Item Type: Incubator Temperature Controller
Material: ABS
Power Supply Voltage: AC110-230V
Power Supply Frequency: 50/60Hz
Temperature Measurement Range: -40-110°C
Temperature Measurement Accuracy: 0.3°C
Humidity Measurement Range: 0%-100% RH
Measurement Accuracy of humidity: 3%
Output control: relay output
Output power: maximum 10A
Installation hole size: approx. 28 x 70 mm / 1.1 x 2.8 inches
Essential Configuration
Start Value > Stop Value (the program automatically determines that the operating mode is cooling/dehumidifying)
Setting the Heating/Cooling Mode
Setting Method:
Setting (Start Temperature): Press and hold button △1, the start temperature will flash, and adjust the start temperature value using button △1▽1.
Setting (Stop Temperature): Press and hold button ▽1 to stop the temperature flashing and adjust the stop temperature value using button △1▽1.
Heating Use Cases:
Control the Water heater, stop heating at 70°C, restart heating when the temperature drops to 45°C and cycle.
Step 1: Heating operating mode, starting temperature. Step 2: Press and hold button △1, the starting temperature will flash, and set the starting temperature to 45°C by pressing button △1▽1.
Step 3: Press and hold button ▽1 to stop the temperature flashing, and set the stopping temperature to 70°C by pressing button △1▽1, and the setting is complete! If there is no operation for 10 seconds, it will automatically return to the normal display state. You can also press △2▽2 to exit immediately.
Refrigeration Use Case:
Used on a livestock farm, the fan stops at 25℃ and the temperature rises to 30℃ to restart the fan.
Step 1: Cooling mode, start temperature > stop temperature.
Step 2: Press and hold button △1, the start temperature will flash, and set the start temperature to 30℃ by pressing button △1▽1.
Step 3: Press and hold button ▽1 to stop the temperature flashing, and set the stop temperature to 25℃ using button △1▽, and the setting is complete! If there is no activity for 10 seconds, it will automatically return to the normal display state. You can also press △2▽2 to exit immediately.
Setting the humidification/dehumidification mode
Setting method:
Setting (start humidity): Press and hold button △2, the start humidity value will flash, and adjust the start humidity value using button △2▽2.
Setting (stop humidity): Press and hold button ▽2 to stop the flashing humidity value and adjust the stop humidity value using button △2▽2.
Example of humidification:
To humidify the supermarket, start humidification at 50% relative humidity and stop humidification when it reaches 80% relative humidity.
Setting steps:
Step 1: Press and hold the Δ2 button to make the humidity value flash and use the △2▽2 button to set the starting humidity value to 50% RH.
Step 2: Press and hold the ▽2 button to stop the humidity value flashing and set the humidity value. Stop the humidity value at 80% RH using the △2▽2 button, and the setting is complete! Press and hold the button for 10 seconds without operation, and it will automatically return to the normal display state, or you can press the △1▽1 button to exit immediately.
Example of dehumidification:
Workshop control exhaust gas dehumidification system, 75% RH humidity starts dehumidification, 45% RH humidity stops dehumidification.
Setting steps:
Step 1: Press and hold the △2 button to make the humidity value flash and use the △2▽2 button to set the starting humidity value. at 75% RH
Step 2: Press and hold the ▽2 button to stop the humidity value flashing, and set the humidity stop value to 45% RH by pressing the △2▽2 button. The setting is complete! Press and hold the button for 10 seconds without operation; it will automatically return to the normal display state, or you can press the △1▽1 button to exit immediately.
Temperature Correction
Temperature Correction: Press and hold the △1▽1 button for 5 seconds to start the digital temperature flashing, and it will display 00. Set the start temperature correction value using the △1▽1 button. Once the setting is complete, press and hold the button for 10 seconds without any further action, and it will automatically return to the normal display state. You can also press the △2▽2 button to exit immediately.
Humidity Correction
Humidity Correction: Press and hold the △2▽2 button simultaneously for 5 seconds to flash the humidity number, display 00, and set the starting humidity correction value using the △2▽2 button. After setting, press and hold the button for 10 seconds without any further action, and it will automatically return to the normal display state. You can also press △1▽1 to exit immediately.


Package List:

1 x Controller

1 x Probe

1 x Manual


Note:

Danger: 1. Strictly distinguish the sensor wire, the power cord, and the output relay interface. Do not connect them incorrectly, and the relay must not be overloaded. 2. All wiring changes must be made with the power disconnected. Warning: This product is prohibited from being used in water or excessively humid environments, and it is prohibited from being used in high-temperature environments, environments with strong electromagnetic interference, and highly corrosive environments.Note: 1. The supply voltage must be consistent with the voltage indicated on the temperature and humidity controller, and the stability of the supply voltage must be ensured. 2. To avoid possible interference, it is recommended to maintain an appropriate distance between the sensor cable and the power line. Note: Non-professionals should not disassemble this product without authorization.

Features

  • Brand
    OTHERS
  • Length
    15 cm
  • Width
    15 cm
  • Height
    35 cm
  • Weight
    2 kg
Advice from

Thermostat buying guide

Thermostats are used to control the temperature of a heating or cooling system to suit the occupant's lifestyle. In addition to making the home more comfortable, a thermostat can help you save on your energy bill. From various models and technologies to extra features, read on to find the best thermostat for your home.
Thermostat buying guide
You are here:
The DIY, home and garden specialist

The DIY, home and garden specialist

Reliable delivery

Reliable delivery

Payment in 3x or up to 30 days free of charge

Payment in 3x or up to 30 days free of charge

More than 7 million individual and professional customers

More than 7 million individual and professional customers