Product information
Description
1、Convert the 0-500 Hz frequency pulse signal into an analog voltage signal of 0-10V. Can be used for interface conversion between PLC and inverter. Or the motion control card and the inverter and other interfaces match the control occasion.
2、The input pulse level of 5V 12V 24V can be directly input, without string resistance. However, the input signal frequency should be maintained for more than 0.5 seconds.The output current is 5mA.
3、The multi-turn potentiometer on the board is used to calibrate the corresponding relationship between frequency and voltage.
4、The input power supply voltage range is 12-30VDC. It is recommended that the power supply voltage be 15-24VDC. When the 12V level is used, the power supply cannot be powered by 12VDC,at least 15VDC power supply is required. When the 24V level is used, th
5、The signal input end is isolated by diaphragm. Guaranteed anti-interference ability.
Features:
Convert the 0-500 Hz frequency pulse signal into an analog voltage signal of 0-10V. Can be used for interface conversion between PLC and inverter. Or the motion control card and the inverter and other interfaces match the control occasion.
The input pulse level of 5V 12V 24V can be directly input, without string resistance. However, the input signal frequency should be maintained for more than 0.5 seconds.The output current is 5mA.
The multi-turn potentiometer on the board is used to calibrate the corresponding relationship between frequency and voltage.
The input power supply voltage range is 12-30VDC. It is recommended that the power supply voltage be 15-24VDC. When the 12V level is used, the power supply cannot be powered by 12VDC,at least 15VDC power supply is required. When the 24V level is used, the power supply needs to be powered by 24VDC.
The signal input end is isolated by diaphragm. Guaranteed anti-interference ability.
Specification:
Item Type:Frequency to Voltage Converter Module
Model:FVS-500Hz10V
Conversion:0~500Hz to 0~10V
Output Current:5mA
Size:7.3 x 5 x 2.8cm / 2.87 x 1.97 x 1.1in
Correspondence Relationship(Linearity)
50Hz converted to 1V
Convert 250Hz to 5V
Convert 500Hz to 10V
Package List:
1 x Converter Module with Shell
Note:
If you need to use PLC, support NPN type. Must have a ground wire.
If you need to use with the encoder, the encoder is required to continue to rotate at a constant speed for more than 0.5 seconds.
Frequency and voltage conversion module, response time is about 0.3-0.5 seconds.
If the signal input is turbine flow, etc., due to signal matching, an 817 diaphragm and a resistor must be added to match the flowmeter to normal function.
Correspondence in use If there is a deviation, you can adjust the blue potentiometer on the board to calibrate. At the time of shipment, we have adjusted the F/v potentiometer to a certain correspondence. It is generally not recommended to adjust it by itself.
Features
- BrandSTUNACY
- Length120 mm
- Conversion typeAC to DC
- ManoMano ReferenceME220941613
- MMID152891397042