Product information
Description
1、Modular design makes it suitable for use with output modules, sensors and remote transmitters.
2、Compact structure, easy to install.
3、Intuitive clear reading, high reliability, measuring accuracy is ±1%.
4、High-definition displays show both instantaneous and cumulative flow.
5、Can be widely used to measure diesel, kerosene, gasoline, etc.
Description: This digitalturbine flow meter has modular design, high accuracy, compact size and stable performance. Easy to replace and maintain internal components. Suitable for use with output modules, sensors and remote transmitters. Features:
Modular design makes it suitable for use with output modules, sensors and remote transmitters.
Compact structure, easy to install.
Intuitive clear reading, high reliability, measuring accuracy is ±1%.
High-definition displays show both instantaneous and cumulative flow.
Can be widely used to measure diesel, kerosene, gasoline, etc.
Specification: Operating voltage: 2.3-3.3V Battery type: 2 x AAA LRO3 batteries Thread size: 1inchNPT Repetition: ±0.5% Measure accuracy: ±1% Maximum working pressure: 20BAR Flow range: 10-90L / Min, 25-150L / Min, 35-250L / Min Single count: 0.00-9999.9 Total cumulative count: 0-999999
Mistakes count: 0.1000-9.9999 Working temperature: -10°C ~ +60°C(14°F~140°F) Standby time: 2 years Application: Diesel, kerosene, gasoline Color: Red, Blue(Optional) Weight: 371g Malfunction and solution:
The flow meter is not accurate.
1. The method
of field calibration is not correct.
Calibrate
again.
2. The flow rate on the meter is below the
lowest.
Increase
the flow rate.
3. The flow meter is blocked by the dry liquid.
Take
out the impeller and clean it carefully and make sure the impeller turns
freely.
4. The impeller is wrapped by the sealing
material.
Remove
the meter and make sure the impeller turns freely.
5. Too close to the impeller.
Install
properly.
6. Too close to the motor or electronic noise
environment
Install
properly.
The reading numbers faded or blanked out.
1.Battery
is exhausted or not connected
Check
the batteries or even replace them.
Flow rate is normal but the meter can not count. Press
the button of DISPLAY, the meter starts.
1.
Field calibration is not correct.
Calibrate
again.
2. The impeller is blocked or
damaged.
Remove
the meter and make sure the impeller turns freely.
3.The impeller is wrapped by the sealing
material.
Remove
the meter and make sure the impeller turns freely.
Flow rate is low and the meter can not count. Press
the button of DISPLAY, the meter starts.
1.
The flow meter is blocked by the dry liquid.
Take
out the impeller, clean it carefully and make sure the impeller turns freely.
2. The flow rate on the meter is below the
lowest.
Increase
the flow rate.
The meter can not calibrate.
1.
Circuit board is break down.
Replace
the circuit board.
2. Button is fail to press.
Replace
the circuit board.