1/3
Timer relay module, dual-MOS 60 34 12 mm DC 5V 36V for controlling motor lights
Buying for your business?
Negotiated prices excl. VAT up to -20%
Sold by Qiudie-homelavafans
You may also like
Compare with similar items
Product information
Description
Features:1.For fast, high-frequency on/off switching, with an unlimited number of switching times.
2.No noise, sparks, or electromagnetic interference during power-on/off.
3.Compared to standard electromagnetic relay modules, it has a longer lifespan.
4.Dual-MOS active parallel output, lower internal resistance, higher current, and higher power; at room temperature, the operating current is up to 15A and the power up to 400W, making it suitable for most equipment.
5.Wide voltage input from 5V to 36V, typically used to control DC motors, lights, LED strips, micro-pumps, solenoid valves, etc., very convenient.
Specifications:Features:
For high-frequency, fast on/off switching, unlimited switching times.
No noise is emitted during power-up/off, no sparking, and no electromagnetic interference.
Compared to normal electromagnetic relay modules, it has a longer lifespan.
Dual-MOS active parallel output, lower internal resistance, higher current, high power; at room temperature, the operating current can reach 15A, the power up to 400W, which can be used for most equipment.
Wide voltage input from 5V to 36V, typically used to control DC motors, lights, LED strips, micro-pumps, solenoid valves, etc., very convenient.
It features an emergency stop function (STOP button) and reverse input protection.
It automatically enters sleep mode and turns off the screen if no operation is performed within 5 minutes, and can be woken up by pressing any button.
You can set different parameters: OP, CL, LOP, which are independent of each other and are saved separately;
All parameter settings will be automatically saved in the event of a power failure.
Specifications:
Voltage: DC 5V ~ 36V.Trigger signal source: High-voltage trigger (3.0V ~ 24V). The signal ground and system ground are not connected to a common ground to improve the system's anti-interference capability (you can also connect them to a common ground).Output capacity: DC 5V ~ 36V, at room temperature, continuous current is 15A, power 400W.With improved heat dissipation, the current can reach 30A.Put-in current: 20mA, operating current: 50mA, operating temperature: -40℃ ~ 85℃, clock range (delay): 0.1 seconds to 999 minutes, size: 60 x 34 x 12 mm.2.36*1.33*0.47"
Instruction:
Operating Mode:
P1: Trigger signal, the relay is activated for the "OP" time, then disconnects; within the "OP" time, as follows:
P1.1: The signal is triggered again, invalid
P1.2: The signal is triggered again, synchronization is reset
P1.3: The signal is triggered again, reset, restarted, and synchronization is stopped. P-2: Trigger signal, the relay turns off "CL" for the specified time, the relay is activated for the "OP" time, then disconnects the relay after the timing.
P3.1: Trigger signal, the relay is activated after the "OP" time; the relay turns off "CL", then the operating cycles begin; if the trigger signal is triggered again during the cycle, the relay turns off, the number of cycles ("LOP") can be set
P3.2: None.Trigger signal after power-up: the relay is activated for the "OP" time, deactivated for the "CL" time, and then the number of operating cycles ("LOP") can be set.
P-4: Signal hold function.If a trigger signal is present, the synchronization is reset, and the relay remains on. When the signal disappears, after the "OP" time has been recorded, the relay is turned off. If another signal is triggered during synchronization, the synchronization will be reset.
How to set the synchronization range:
After setting the parameter value when selecting the mode, press the "STOP" button to set the synchronization range;
XXX.The last decimal point is illuminated; range: 1 second to 999 seconds.
XX. X The second-to-last decimal point lights up, range: 0.1 seconds to 99.9 seconds
X. X. X. The three decimal points light up, range: 1 minute to 999 minutes.
For example, if you want to set "OP" to 3.2 seconds, light up the second-to-last decimal point and set the digital display to 03.2.
Parameter description: "OP" - hour, "CL" - stop time, "LOP" - number of cycles (1 to 999 times, "---" represents an infinite loop).
These parameters are independent of each other but are shared by each mode.For example, in P1.1 mode, set the "OP" operating time to 5 seconds. If you switch to P1.2 mode, its "OP" will also be 5 seconds.
In the main interface (display 000), press the "SET" button to display "OP" ("CL", "LOP") and the corresponding time XXX;
If the mode (such as mode P1.1, P1.2, P1.3) only displays the time "OP", press the "SET" button to display only "OP" and the corresponding time;
Some models (such as mode P3.1, P3.2) have the parameters "OP", "CL", "LOP", press the "SET" button to display "OP" and the corresponding time, "CL".and the corresponding time, "LOP", and the corresponding number of times;
After setting the mode, in the main interface, press the "SET" button to view information about the parameters of the current mode, which is very convenient.
How to set the parameters:
1. Start by reading the instructions to determine the required operating mode.
2.The module is powered on, the display is in the current working mode (default mode P1.1), then enter the main interface; press and hold the "SET" button for 2 seconds to access the mode selection interface; then press the "UP" and "DOWN" buttons to select the mode (P1.1 ~ P-4).
3.Select the mode (such as P3.2), then press the "SET" button. The parameter to be set will flash ("OP" activation time, "CL" deactivation time, "LOP" cycles ("---" represents infinite loop)). Press (or press and hold) the "UP" and "DOWN" buttons to set the parameter value; then press the "STOP" button to adjust the decimal point position to select the clock range (0.1 seconds to 999 minutes); press the "SET" button to set the following parameters of the
2.No noise, sparks, or electromagnetic interference during power-on/off.
3.Compared to standard electromagnetic relay modules, it has a longer lifespan.
4.Dual-MOS active parallel output, lower internal resistance, higher current, and higher power; at room temperature, the operating current is up to 15A and the power up to 400W, making it suitable for most equipment.
5.Wide voltage input from 5V to 36V, typically used to control DC motors, lights, LED strips, micro-pumps, solenoid valves, etc., very convenient.
Specifications:Features:
For high-frequency, fast on/off switching, unlimited switching times.
No noise is emitted during power-up/off, no sparking, and no electromagnetic interference.
Compared to normal electromagnetic relay modules, it has a longer lifespan.
Dual-MOS active parallel output, lower internal resistance, higher current, high power; at room temperature, the operating current can reach 15A, the power up to 400W, which can be used for most equipment.
Wide voltage input from 5V to 36V, typically used to control DC motors, lights, LED strips, micro-pumps, solenoid valves, etc., very convenient.
It features an emergency stop function (STOP button) and reverse input protection.
It automatically enters sleep mode and turns off the screen if no operation is performed within 5 minutes, and can be woken up by pressing any button.
You can set different parameters: OP, CL, LOP, which are independent of each other and are saved separately;
All parameter settings will be automatically saved in the event of a power failure.
Specifications:
Voltage: DC 5V ~ 36V.Trigger signal source: High-voltage trigger (3.0V ~ 24V). The signal ground and system ground are not connected to a common ground to improve the system's anti-interference capability (you can also connect them to a common ground).Output capacity: DC 5V ~ 36V, at room temperature, continuous current is 15A, power 400W.With improved heat dissipation, the current can reach 30A.Put-in current: 20mA, operating current: 50mA, operating temperature: -40℃ ~ 85℃, clock range (delay): 0.1 seconds to 999 minutes, size: 60 x 34 x 12 mm.2.36*1.33*0.47"
Instruction:
Operating Mode:
P1: Trigger signal, the relay is activated for the "OP" time, then disconnects; within the "OP" time, as follows:
P1.1: The signal is triggered again, invalid
P1.2: The signal is triggered again, synchronization is reset
P1.3: The signal is triggered again, reset, restarted, and synchronization is stopped. P-2: Trigger signal, the relay turns off "CL" for the specified time, the relay is activated for the "OP" time, then disconnects the relay after the timing.
P3.1: Trigger signal, the relay is activated after the "OP" time; the relay turns off "CL", then the operating cycles begin; if the trigger signal is triggered again during the cycle, the relay turns off, the number of cycles ("LOP") can be set
P3.2: None.Trigger signal after power-up: the relay is activated for the "OP" time, deactivated for the "CL" time, and then the number of operating cycles ("LOP") can be set.
P-4: Signal hold function.If a trigger signal is present, the synchronization is reset, and the relay remains on. When the signal disappears, after the "OP" time has been recorded, the relay is turned off. If another signal is triggered during synchronization, the synchronization will be reset.
How to set the synchronization range:
After setting the parameter value when selecting the mode, press the "STOP" button to set the synchronization range;
XXX.The last decimal point is illuminated; range: 1 second to 999 seconds.
XX. X The second-to-last decimal point lights up, range: 0.1 seconds to 99.9 seconds
X. X. X. The three decimal points light up, range: 1 minute to 999 minutes.
For example, if you want to set "OP" to 3.2 seconds, light up the second-to-last decimal point and set the digital display to 03.2.
Parameter description: "OP" - hour, "CL" - stop time, "LOP" - number of cycles (1 to 999 times, "---" represents an infinite loop).
These parameters are independent of each other but are shared by each mode.For example, in P1.1 mode, set the "OP" operating time to 5 seconds. If you switch to P1.2 mode, its "OP" will also be 5 seconds.
In the main interface (display 000), press the "SET" button to display "OP" ("CL", "LOP") and the corresponding time XXX;
If the mode (such as mode P1.1, P1.2, P1.3) only displays the time "OP", press the "SET" button to display only "OP" and the corresponding time;
Some models (such as mode P3.1, P3.2) have the parameters "OP", "CL", "LOP", press the "SET" button to display "OP" and the corresponding time, "CL".and the corresponding time, "LOP", and the corresponding number of times;
After setting the mode, in the main interface, press the "SET" button to view information about the parameters of the current mode, which is very convenient.
How to set the parameters:
1. Start by reading the instructions to determine the required operating mode.
2.The module is powered on, the display is in the current working mode (default mode P1.1), then enter the main interface; press and hold the "SET" button for 2 seconds to access the mode selection interface; then press the "UP" and "DOWN" buttons to select the mode (P1.1 ~ P-4).
3.Select the mode (such as P3.2), then press the "SET" button. The parameter to be set will flash ("OP" activation time, "CL" deactivation time, "LOP" cycles ("---" represents infinite loop)). Press (or press and hold) the "UP" and "DOWN" buttons to set the parameter value; then press the "STOP" button to adjust the decimal point position to select the clock range (0.1 seconds to 999 minutes); press the "SET" button to set the following parameters of the
Features
- BrandOTHERS
- ColourMulticolour
- MaterialPlaster
- ManoMano ReferenceME242430964
- MMID453168548225
- Product codeQD-GB26Y63514
- EAN5008500135043
You are here:


















