Product information
Description
Features:
1. A variety of perfect applications, convenient operation and settings, is your ideal temperature control controller.
2. It is accurate and reliable with good long-term stability. Convenient to install and repair. Small size, low power consumption, fast response.
3. Easy operation, for setting the start temperature, stop temperature, corrected temperature connector, etc.
4. Suitable for hatching, breeding, air and water temperature control and other related temperature detection and control applications.
5. Specifications are optional, precise temperature control, temperature calibration.
Specifications:
Item Type: Digital Temperature Controller
Material: Plastic
Weight: Approx. 51 g / 1.8 oz
Specifications
V, 24 V, 110-220 V Accuracy level: 0.1
Temperature measurement range: -50-110 (℃)
Temperature measurement accuracy: -15-65 (℃)
Humidity measurement accuracy: 1 (RH)
Temperature measurement error: ±1 (℃)
Applicable environment: -15-55 ℃ / 20%-85% RH Built-in hole in product
Size: 73 mm / 2.9 inches, hole diameter (φ4 mm)
How to use:
1. Press the adjustment button once to access the internal menu. The default display is P0. Press the adjustment button again and set the required start temperature using the up and down buttons.
2. Press the adjustment button once to access the internal menu. The display is P0. Switch to P1 using the up and down buttons. Press the adjustment button again and set the required stop temperature using the up and down buttons.
3. Enter the internal menu in the same way, navigate to P2 using the up and down buttons, press the adjustment button again, and set the required calibration temperature using the up and down buttons.
(Note: During adjustment, if the detected temperature value is 0.5°C higher than the actual temperature value, then the calibration temperature to be set is -0.5°C. If the detected value is 1°C lower than the actual value, the calibration temperature to be set is 1°C. Detection Temperature + Correction Temperature = Actual Temperature.)
4. Enter the internal menu in the same way, go to P3 by pressing the up and down buttons, press the setting button again, and set the required delay time in minutes using the up and down buttons.
(Note: Delayed start is generally used for compressor refrigeration. If used for refrigerators and freezers, this value must be set.)
Depending on the compressor back pressure, the general setting value is 3 to 6 minutes. If you are not using it for control or no delay function is needed, simply skip it.
Temperature Control Mode
1. Essential Setting Parameters: Start Temperature
2. Setting Method: Press the setting button to access the internal menu, set the start temperature via value P0 and set the stop temperature via value P1. Use Case: Control the water heater, stop How do I set the heating mode to 50°C and restart heating when the temperature returns to 40°C?
1. Ensure the operating mode is set to heating, start temperature
2. Press the setting button to access the internal menu, select P0 to start heating, and set the P0 value to 40°C. 3. Press the Set button to access the internal menu, select P1 to stop heating, and set the P1 value to 50°C. Cooling Mode
1. Essential setting elements: start temperature > stop temperature (the program automatically determines that the operating mode is cooling)
2. Setting method: Press the setting button to access the internal menu, set the start temperature via P0 and set the stop temperature via the P1 value
1. Use case: empty cabinet radiator, heat dissipation The temperature stops at 26°C and rises to 30°C. To restart the radiator, how do I adjust it?
1. Ensure the operating mode is set to Cooling mode, Start Temperature > Stop Temperature.
2. Press the adjustment button to access the internal menu, select P0 to start temperature adjustment, and set the P0 value to 30°C.
3. Press the adjustment button to access the internal menu, select P1 to stop temperature adjustment, and set the P1 value to 26°C.
Package List:
1 x Temperature Controller
Note:
1. Press and hold the up and down buttons simultaneously until the screen displays 888 to restore factory settings.
2. The screen displays LLL, indicating that the temperature sensor If the sensor is not connected, disconnected, or damaged, simply replace it. 3. The HHH display indicates that the temperature probe is short-circuited and exceeds its temperature detection range.
Features
- BrandOTHERS
- SmartNo
- ColourWhite
- MaterialPlastic
- Thermostat typeCorded
- ManoMano ReferenceME226178631
- MMID327435481000
- Product code4048091699457
- EAN4048091699457