Skip to main content
1/5

1P+N C16A curve C 6kA EN61009 RCBO

(£5.76/pcs)

Product information

Description

1) Combined 2-in-1 protection for enhanced everyday safetyThis 1P+N C16A modular RCBO combines in a single device protection against overloads and short circuits (circuit breaker function) and residual current protection (detection of leakage currents). It helps reduce the risks of electrocution and electrically caused fire by automatically cutting off the power supply as soon as an anomaly is detected: prolonged overload, direct short circuit, insulation fault, moisture causing leakage to earth, equipment whose casing accidentally becomes live, etc. It is a relevant solution for making an electrical consumer unit more reliable in environments where personal safety is a priority and where more complete protection than a simple miniature circuit breaker is desired.2) European format for electrical consumer unit, ideal for residential and small commercial premisesDesigned for integration into a distribution enclosure (modular consumer unit), this model is well suited to the needs of residential installations and small premises: house, flat, office, local shop, studio, student room, rental property, etc. It is particularly suitable for common circuits such as sockets and the power supply of small household appliances, as well as certain lighting circuits depending on the design of the installation. Thanks to its combined protection logic, it provides a simple solution for upgrading a circuit outgoing way by adding the residual current function, particularly in areas where moisture may increase the risk of a fault (kitchen, utility room, technical rooms… while complying with local installation requirements).3) 1P+N architecture: “cleaner” disconnection and easier maintenanceThe 1P+N (phase + neutral) configuration allows simultaneous switching of the phase and the neutral. In practice, this improves the quality of the circuit isolation during tripping or intervention: a cleaner disconnection is achieved, and the maintenance/diagnostic operation is generally more reassuring, particularly in installations where the identification or distribution of neutrals may be a source of errors. This choice is very common in single-phase systems to protect a circuit outgoing way by combining personal safety and continuity of service, while retaining a modular layout compatible with European installation practices.4) Key technical characteristics for a clear choice (C16A version, 6 kA)Rated current: 16 A (current rating for socket circuits and standard domestic uses, to be sized according to conductor cross-section and the actual power demand).Tripping curve: type C, better able to tolerate the starting current peaks of certain equipment (small motors, compressors, fans…), which helps limit nuisance tripping on start-up while maintaining effective protection in the event of a fault.Breaking capacity: 6 kA, enhanced breaking capacity in the event of a short circuit, suitable for domestic/commercial consumer units according to the installation short-circuit study.Voltage / frequency: AC 230–400 V, 50–60 Hz, covering common AC environments (single-phase and certain distribution contexts).Compliance: EN 61009, reference standard for devices combining a circuit breaker and residual current protection (RCBO).Important note: as the residual current sensitivity (e.g. 30 mA), tripping time, exact dimensions and other data are not provided, they are not indicated here in order to avoid any approximate information. For residual current protection, sensitivity is a determining selection criterion.5) Installation and usage advice (good on-site practice)For reliable operation, it is recommended to entrust installation to a qualified electrician, respecting upstream/downstream identification, terminal tightening and circuit balancing. In the event of repeated tripping, the most frequent causes are: overload (too many devices on the same outgoing way), cable insulation fault, defective appliance (leakage), or poor tightening causing overheating. A simple method is to disconnect the loads and then reconnect them one by one in order to identify the circuit or appliance at fault, and if necessary to carry out measurements (insulation/residual current) with the appropriate tools. For residual current devices, periodic checking according to the device fitted (test button or test procedure) is also good practice, in accordance with common practice and the applicable regulations.

Features

  • Brand
    OTHERS
  • ManoMano Reference
    ME222479585
  • MMID
    509487708252
  • Product code
    LXCMANO-00897
  • EAN
    5901447855831
You are here:
The DIY, home and garden specialist

The DIY, home and garden specialist

Reliable delivery

Reliable delivery

Payment in 3x or up to 30 days free of charge

Payment in 3x or up to 30 days free of charge

More than 7 million individual and professional customers

More than 7 million individual and professional customers