640V Overcharging and Undervoltage Protection Board Timing Charging/Discharging Protector

Sold by STUNACY

You may also like

Compare with similar items

Product information

Description

1、Battery charge and discharge control, automatically set off after setting.

2、Can set the charge and discharge time accurately recording to your needs.

3、With serial communication function, the working status of the relay can be monitored in real time through the serial port.

4、An additional signal output, when the relay conduction condition is met, the output level is high, and other devices can be controlled.

5、One button emergency stop function (STOP button), with reverse connection protection, reverse connection does not burn.

Features:

Battery charge and discharge control, automatically set off after setting.

Can set the charge and discharge time accurately recording to your needs.

With serial communication function, the working status of the relay can be monitored in real time through the serial port.

An additional signal output, when the relay conduction condition is met, the output level is high, and other devices can be controlled.

One button emergency stop function (STOP button), with reverse connection protection, reverse connection does not burn.

Specification:

Power Voltage: DC6~40V

Voltage Detection Range:0~60VDC

Voltage Measuring Error:+-0.1V

Suitable for :Battery below 60V

Charging and Discharging Time Setting:0~999m

Serial Port Control(SCM TTL level communication):

Communication Standard: Baud Rate 115200 Bps

Data Bit : 8

Stop Bit :1

Check Digit :None

Flow Control : None

Size:6.4 x 4cm / 2.52 x 1.57in

Package List:

1 x Charge Discharge Protection Board

Users Manual:

1. First determine the operating mode of the relay;

2. According to the working mode of the relay, in the main interface (when the module is powered on, it will flash the current working mode (default U-1 mode), then enter the main interface), long press the SET button for 2 seconds and then release , enter the mode selection interface, select the mode to be set (U-1~U-6) by short pressing the UP and DOWN buttons;

3. After selecting the mode to be set (for example, U-1), press the SET button to set the corresponding parameter. At this time, the parameter to be set will flash (UL1 voltage upper limit, nL1 voltage lower limit, OP ON time), through UP, DOWN adjust the parameter value, support long press (rapid increase or decrease) and short press (increase or decrease 1 unit); short press SET button to set the next parameter of the current mode, the process is the same as above;

4. After setting the parameters of the selected mode, press and hold the SET button for 2 seconds to release, the currently set mode will flash, then return to the main interface, setting the parameters successfully, very simple!

5. In the main interface, short press the DOWN button to switch between voltage and time, which is very simple.

Mode selection interface: long press SET button to enter, after setting is completed, long press SET button to exit, return to the main interface, very simple!

Serial Command:

\"U-1\": working mode (value range U-1 ~ U-6)

''000'': Time parameter 0: Do not enable timing function Non-0: Enable timing function (value range 000~999)

\"dw02.9\": set the lower limit voltage

\"up10.1\" : Set the upper limit voltage (value range 00.0V~60.0V)

\"get\": Get current settings

\"on\": Allow relay to conduct

\"off\": Always turn off the relay

\"start\": Start uploading data

\"stop\": Stop uploading data

The above commands can be combined in any two, and need to be separated by commas.

Such as: \"dw02.9,up10.1\" Set the lower limit voltage 02.9V upper limit voltage 10.1V

Upload status: test voltage + on time + status

"00.0V, 00:00:00, OP\\r\\n"

00.0V : measured voltage

00:00:00 : Relay conduction time

Status: OP relay is on CL relay is off

Relay Using Mode:

1. ON: The relay is allowed to conduct during the OP conduction time;

2. OFF: The relay is prohibited from being turned on and is always off.

Short press the STOP button on the main interface to switch between ON and OFF. The current state will flash and then return to the main interface. (This function is the emergency stop function, one button to open and close the relay)

Sleeping Mode:

1. C-P sleep mode: within five minutes, without any operation, the digital tube automatically turns off the display and the program runs normally;

2. O-d normal mode: the digital tube is always on display;

Press and hold the STOP button for 2 seconds and then release it to switch between C-P and O-d. The current state will flash and return to the main interface.

Features

  • Brand
    STUNACY
  • ManoMano Reference
    ME220940384
  • MMID
    987788666858
  • Product code
    STYM-GS20896
  • EAN
    4265116038101
Advice from

Wind turbine buying guide

Interest in domestic wind turbines in the UK increases year after year. Ideal for a countryside home, but trickier to set up in a city, wind turbines can be a great way to get into renewable energy and off-grid energy production. Read on to find out more about installing a wind turbine for more sustainable living.
Wind turbine buying guide
You are here:
The DIY, home and garden specialist

The DIY, home and garden specialist

Reliable delivery

Reliable delivery

Payment in 3x or up to 30 days free of charge

Payment in 3x or up to 30 days free of charge

More than 7 million individual and professional customers

More than 7 million individual and professional customers