7‑30V 0‑30A DC Current Detection Sensing Module Overcurrent Protection Relay Module

£21.99
Sold by STUNACY

You may also like

Compare with similar items

Product information

Description

1、This module can detect the DC current value, control the on‑off of the relay according to the limit current set by users.

2、Detection range is DC 0‑30A with the accuracy of 0.01A.

3、With error calibration function.

4、Can turn off the LED display to reduce power consumption.

5、Can be used to limit the current in the circuit, protect electrical equipment from damage caused by current.

Features:

This module can detect the DC current value, control the on-off of the relay according to the limit current set by users.

Detection range is DC 0-30A with the accuracy of 0.01A.

With error calibration function.

Can turn off the LED display to reduce power consumption.

Can be used to limit the current in the circuit, protect electrical equipment from damage caused by current.

Specification:

Model: YYI-4

Supply voltage: DC 7-30V

Detection range: DC 0-30A

Accuracy: 0.01A (10mA)

Standby current: About 20mA

Weight: Approx. 86g/3.0oz

Function description:

P-11: When the measured current > I1 (low limit current), the relay closed; When the measured current < I1, the relay opens;

P-12: When the measured current > I1, the relay closes; Maintain the state until the circuit board power off;

P-21: When the measured current > I2 (high limit current), the relay closes; When the measured current < I1, the relay opens;

P-22: When the measured current > I2, the relay closes; Maintain the state until the circuit board power off;

P-31: When measured < I1, the relay closes; When the current > I2, the relay opens;

P-32: When the measured current < I1, the relay closes; Maintain the state until the circuit board power off;

P-41: When the measured current is between I1 and I2, the relay closes, opens in other cases;

P-42: When the measured current is between I1 and I2, the relay closes; Maintain the state until the circuit board power off;

P-51: When the measured current < I1 or > I2, the relay closes, opens in other cases;

P-52: When the measured current < I1 or > I2, the relay closes; Maintain the state until the circuit board power off.

Settingdescription:

Power on, display the measured current; (if the measured current terminal is none, the LED digits will pulse)

Press K1 for the second time (for over 1s to prevent misoperation)

, the screen shows: P11, k2 adjusts mode, K3 adjusts function

Press K1 for the second time, the screen flashes: 0.05, means the threshold I1 is 0.05A, K2 increases I1, K3 increases I1

Press K1 for the third time, the screen flashes: 0.10, means the threshold I2 is 0.1A; K2 increases I2, K3 increases I2

Press K1 for the fourth time, the screen shows the measured current , enters the standby state

Long press K2 or K3 in standby state to fine-tune the error of the measured current

Package list:

1 * DC Current Detection Module

Features

  • Brand
    STUNACY
  • ManoMano Reference
    ME215570847
  • MMID
    879087042508
  • Product code
    STYM0512-GS10835
  • EAN
    4970488617433
You are here:
The DIY, home and garden specialist

The DIY, home and garden specialist

Reliable delivery

Reliable delivery

Payment in 3x or up to 30 days free of charge

Payment in 3x or up to 30 days free of charge

More than 7 million individual and professional customers

More than 7 million individual and professional customers