Skip to main content
1/5

AC 100-240V Digital LED Temperature Controller Thermostat with Air Sensor TMC-6000

£27.99
Sold by STUNACY

You may also like

Compare with similar items

Product information

Description

1、One-way 10K NTC temperature sensor input

2、 One-way NO & NC output

3、Temperature display

4、 Shifting between the refrigerating and heating modes

5、Delay protection of compressor

Product function introduction:

The one-way temperature controller can set as

"refrigerating" or "heating", using 10K general NTC

thermistor to control temperature, control the one-way relay (NO, NC) output.

The temperature range controlled is -45℃-110℃. It is used extensively in various refrigerating and

heating situations.

Under refrigerating mode, the output opens

when the temperature is above (temperature control value + backlash), and stops

when temperature is the at temperature control value.

Under heating mode, the output opens when the

temperature is below (temperature control value - backlash), and stops when

temperature is the at temperature control value.

The temperature control value and backlash

are adjustable. Correction function for temperature deviation is also available.

DIN rail-type installation is adopted which

is easy and fast for installing.

The advanced design of isolating power supply

is adopted, which can ensure the controller work steadily, reliably, and

continuously when the power supply changes between 100V and 240VADC.

Main Features:

One-way 10K NTC temperature sensor input

One-way NO NC output

Temperature display

Shifting between the refrigerating and heating modes

Delay protection of compressor

Correction of measured temperature deviation

Power-down memory protection function

Panel introduction

1.The indicator light is lit when the relay NO pulls-in.

2. LED display window: temperature is displayed during work (T temperature =

T temperature measured + T deviation)

3. (erected triangle)is parameter plus adjust key under set state; Under work

state, press it for long to check the temperature control value set.

4. (SET) set key, press it to start the parameter set state and press one by one

to shift to display each parameter.

5. (Inverted triangle)is parameter minus adjust key under set state.

6. If no action is conducted in 3 min after adjusting, the interface will

return to the main interface automatically, displaying current temperature.

Detailed introduction of the control

function:

Short name of control function

Control function introduction

Other introduction

Temperature measuring correction

Displayed T temperature = T measured temperature + T

deviation

Temperature control output

1. Under H mode, when T temperature≥T temperature control, the relay NO is off, output

stops; when T temperature is2. Under L mode, when the T temperature≤T temperature control, the relay NO is off, output

stops; when T temperature is>(T temperature + T backlash), the relay NO pulls-in again,

refrigerating output starts;

The time for relay output open-- close or close-- open

shall not be shorter than the Pt set value.

Operation guide:

Press(SET)to start setting parameter, press one by one to

shift to display each parameter; (erected triangle)(Inverted triangle )is used

to adjust the value. After setting, press continuously the(SET) key until the

main interface is get.

Times

pressing(SET)

Display

Parameter

explanation

Function

introduction and short name

Parameter

set range

Factory

setting

1

-H-

HL

Selection

of heating/refrigerating (H is heating mode, L is refrigerating mode)

H/L

H

2

-1-

Parameter

1

3

Upper

limit of temperature control

Temperature

control value when relay NO output stops

-45-110℃

25℃

4

-2-

Parameter

2

5

d

Temperature

control backlash value

1-30℃

2℃

6

-3-

Parameter

3

7

Delay time, controlling the minimum delay time of

the relay output open-- close or close-- open (the delay time should be set

as 2-3 min for refrigerating compressor for protection)

0-300 S

1S

8

-4-

Parameter

4

9

SC

Correction

of measured temperature deviation

-25-25℃

0℃

Technical Parameter:

External dimension (mm):L 93 x W 55 x H 44

Installation mode:The controller installation could be standard DIN rail

installation or fixed installation

Power supply and consumed

power at work:ADC(100-240)V,2W

Application environment:-10℃-50℃

Display mode:Three LED digit display

Key:Press-type membrane key

Input:One-way (10K)NTC thermistor temperature sensor output,

measuring range of -50℃-120℃

Output:

1. One-way relay NO, NC refrigerating/heating output

2. The

current capacity of the output contact is 5 ampere of restrictive load and 1

ampere of inductive load. It can control the 1000W electrical heating or

electrical motor or water pump of 200W. A.C. contactor is needed to enlarge the

capacity for more load.

Measurement range:-50℃-120℃

Set range:

Minimum limit: -45℃-controlled temperature

Maximum

limit: controlled temperature-110℃

Control range:-45-110℃

Other parameter:

1. The temperature sensing line could be connected with

general wire for 100 meters

2. Set the parameter to conserve long-term memory of

power-down

3. Temperature control backlash is 1-30℃

4. Delay time: 0-300 S

5.

Deviation correction: -25 -25℃

Remark:The max load current of this product is 10A, so please

ensure an allowance (around 6A) during long-term using to increase the using

time. The parameters and set in this guide are those when the load connects

onto the NO end. If connection onto the NC end is required, please set accordingly.

Connection and installation:

L (firing line), N connects power supply:

100-250VAC

N: common terminal, connecting one end of the

load

NO: normally open, connecting the other end

of the load

NC: normally close

Safety precautions

1. The temperature sensor is easily damaged if it touches

water, so please keep sealing with no water leakage after the (sensor probe) is

inserted into the (waterproof blind tube).

Do not directly put the (sensor) into the water for

measuring temperature.

2. Please do not put the transmission line of the

temperature sensor at the same wire duct with the 220V high-voltage wire to

avoid disturbance of strong current to the controller.

3.The temperature sensor can be connected with two-core

electrical wire for prolong.

4.Output load: restrictive

load is 220V/5A; inductive load is 220V/1A.

The temperature sensor is a 10K thermistor

restrictive sensor where B=3950 with many advantages of high accuracy of

temperature measuring, excellent steadiness and very low temperature drift. The

user can prolong the sensor by connecting with two-core wire with an effective

extension of 100 meters.

Temperature sensor probe needs to measure the

water temperature in a waterproof blind tube for isolation, so that the sensor

can be durable in use. Direct measuring in the water shall damage it easily.

Package Included:

1 xMain frame

1 x NTC (10K) one temperature sensing line

1 x Instructions

Features

  • Brand
    STUNACY
  • ManoMano Reference
    ME215566483
  • MMID
    573837644031
  • Product code
    STYM0512-GS01420
  • EAN
    4970488578352
You are here:
The DIY, home and garden specialist

The DIY, home and garden specialist

Reliable delivery

Reliable delivery

Payment in 3x or up to 30 days free of charge

Payment in 3x or up to 30 days free of charge

More than 7 million individual and professional customers

More than 7 million individual and professional customers