Skip to main content
1/5

Controller of temperature digital by micro-computer XH‑3002, controller hatching 12V

£25.83
Of which environmental contribution £0.01 including VAT.

Buying for your business?

Negotiated prices excl. VAT up to -20%

Sold by HERSAMA

Product information

Description

Features:

1. A variety of fields use perfect, a operation practical and settings practical, is your gouvernante of control of the temperature side.

2. It is precise and reliable with a good stability to long term. Practical for install and repair. compact size, low energy consumption, response fast.

3. Operation easy, for adjust the temperature of start, the temperature stop, the connector of temperature corrigee, etc.

4. suitable for hatching, livestock, the control of the temperature of air and of water and other detection and soumise of temperature connexes.

5. The specifications are steelspecifications, control precise of the temperature, calibration of the temperature.

Specifications:

Item Type : controller of temperature digital

Material : plastic

Weight : approx. 51 g / 1,8 oz

Specifications of voltage of operation : 12 V, 24 V, 110-220 V

Level of precision : 0,1

Range of measurement of the temperature : -50-110 (℃)

Precision of the measurement of the temperature : -15-65 (℃)

Precision of the measurement of moisture : 1 (RH)

Error of measurement of the temperature : ±1 (℃)

Environment applicable : -15-55 ℃ / 20 %-85 %RH

Hole integrated to the product Size : 73 mm / 2,9 inches, diameter of the hole (φ4 mm)

How to Use : 1. Press a times on the button of adjustment for access to the menu internal, display by fault is P0, press to new on the button of adjustment and adjust the temperature of start required to helps buttons high and bottom. 2. Press a times on the button of adjustment for access to the menu internal, display is P0, pass to P1 via the buttons high and bottom, press to new on the button of adjustment and adjust the temperature stop required via the buttons high and bottom. 3. Entrez in the menu internal of the same way, pass to P2 via the buttons high and bottom, press to new on the button of adjustment and adjust the temperature calibration required via the buttons high and bottom. (Note : in the adjustment, if the value of temperature detected is 0,5°C upper to the value of temperature actual, then the temperature calibration which must be adjusted is of -0,5°C. If the value detected is 1°C lower to the value actual. Value of temperature, the temperature calibration which must be adjusted is of 1 °C. Temperature of detection + Temperature of correction = Temperature actual.) 4. Entrez in the menu internal of the same way, pass to P3 in press on the buttons high and bottom, press to new on the button of adjustment and adjust the time of delay required via the buttons high and bottom in minutes. (Note : the start differ is generally used for the refrigeration by compressor. It is used for the refrigerators and the congelateurs, this value must be adjusted. According the against-pressure of the compressor, the value of adjustment general is of 3 to 6 minutes. If you are not not used for the control or no function of delay is not necessary, sautez-la simply. Mode of control of the temperature 1. Settings essential of adjustment : Temperature of start 2. Method of adjustment : press on the button of adjustment for access to the menu internal, adjust the start. temperature via the value P0 and adjust the temperature stop via the value P1 Case use : Control the heater, stop of heat to 50°C and recommencer to heat when the temperature revient to 40°C, how the adjust ? 1. make sure that the mode of operation is the mode heating, temperature of start 2. Press on the button of adjustment for access to the menu internal, select P0 for start the temperature and adjust the value P0 on 40°C. 3. Press on the button Set for access to the menu internal, select P1 for stop the temperature and adjust the value of P1 on 50 ℃ Mode of cooling 1. Components essential of adjustment : temperature of start> temperature stop (the program juge automatically that the mode of operation is the mode of cooling) 2. Method of adjustment : press on the button of adjustment for access to the menu internal, adjust the temperature of start via the P0 and adjust the temperature stop via the value P1. Case use : radiator cabinet empty, the heat dissipation stops to 26 ℃ and the temperature increase. to 30 ℃ for redemarrer the radiator, how the adjust ? 1. make sure that the mode of operation is the mode cooling, temperature of start> temperature stop. 2. Press on the button of adjustment for access to the menu internal, select P0 for start the change of temperature and adjust the value P0 on 30 °C. 3. Press on the button of adjustment for access to the menu internal, select P1 for stop the temperature and adjust the value of P1 to 26 ℃.

Package List:

1 x controller of temperature

Note:

1. Press and now pressed in the buttons high and bottom at the same time, attendez that screen displayed 888 for restore the settings factory.2. Screen displayed LLL, apparat that the probe of temperature is not connect, disconnected or damaged, replacement-the simply.3. Screen HHH indicates that the probe of temperature is in short-circuit and exceeds the range of detection of temperature.

Features

  • Brand
    BEIJIYI
  • Material
    Plastic
  • ManoMano Reference
    ME245820666
  • MMID
    650791672933
  • Product code
    GB05952
  • EAN
    9306497168379
Chicken coop buying guide
Advice

Chicken coop buying guide

Read our guide
You are here:
The DIY, home and garden specialist

The DIY, home and garden specialist

Reliable delivery

Reliable delivery

Flexible payment options

Flexible payment options

More than 7 million individual and professional customers

More than 7 million individual and professional customers