1、Current Sensor Module: Can easily detect the DC current and control the on and off of relay according to the set limit current.

2、Wide Detection Range: The voltage detection range is 7‑30V, and the current detection range is 0‑30A, meeting various needs.

3、Accurate Measurement: With a high measurement accuracy up to 0.1A, the sensor module has error calibration function as well.

4、Circuit Protection: Used to limit the current in the circuit and protect electrical equipment from damage caused by the current.

5、Convenient Operation: The digital display can be turned off for a long time to reduce power consumption, useful and convenient.Item Type: Current Detection Module

Product Model: YYI-4

Voltage Detection Range: DC7-30V

Current Detection Range: 0~30A

Detection Accuracy: 0.1A (100mA).

Standby Current: About 20mA.

Relay Output: Can control the on and off of DC lines within 30A.

Function: Detect whether the current is too large or too small, control the relay switch to control the line on and off, or give a signal.

How to Use:

No. 1 Operation Instructions:

1. P-11: When the measured current is greater than I1, the relay is closed; when the measured current is less than I1 again, the relay is disconnected;

2. P-12: When the measured current is greater than I1, the relay is closed; it always stays closed until the circuit board is powered off;

3. P-21: When the measured current is greater than I2, the relay is closed; when the measured current is less than I1, the relay is disconnected;

4. P-22: When the measured current is greater than I2, the relay is closed; it always stays closed until the circuit board is powered off;

5. P-31: When the measured current is less than I1, the relay is closed; when the current is greater than I2, the relay is disconnected;

6. P-32: When the measured current is less than I1, the relay is closed; it always stays closed until the circuit board is powered off;

7. P-41: When the measured current is between I1 and I2, the relay is closed, otherwise the relay is disconnected;

8. P-42: When the measured current is between I1 and I2, the relay is closed; it always stays closed until the circuit board is powered off;

9. P-51: When the measured current is less than I1 or greater than I2, the relay is closed, otherwise the relay is disconnected;

10.P-52: When the measured current is less than I1 or greater than I2, the relay will be closed; it will always be closed until the circuit board is powered off.

No. 2 Setting Instructions:

1. Power on to display the measured current(if the measured current terminal is suspended, the number of digital display is normal);

2. The first time K1 is pressed, it takes more than 1 second to effective prevent false triggering. The screen displays: P 11: K2 adjustment mode, K3 adjustment function

3. Press K1 for the second time, the screen flashes 0.05 means that the value of the threshold I1 is 0.05A; K2 sets I1 plus, K3 sets I1 minus;

4. Press K1 for the third time, the screen flashes 0.10 means the value of the threshold I2 is 0.1A; K2 sets I2 plus, K3 sets I2 minus

5. Press K1 for the fourth time, the screen displays the measured current; it means it enters the standby state;

6. In standby mode, long press K2 or K3 to fine tune the measured current error. 1 x Current Detection Module

Features

  • Brand
    STUNACY
  • ManoMano Reference
    ME215562109
  • MMID
    320678079616
  • Product code
    STYM0512-1010210154411
  • EAN
    4970488536581
You are here:
The DIY, home and garden specialist

The DIY, home and garden specialist

Reliable delivery

Reliable delivery

Payment in 3x or up to 30 days free of charge

Payment in 3x or up to 30 days free of charge

More than 7 million individual and professional customers

More than 7 million individual and professional customers