Skip to main content
1/5

DC 5V--36V Trigger Cycle Delay Timer Switch Turn On Off Relay Module with LED Display

£11.99
Sold by STUNACY

You may also like

Compare with similar items

Product information

Description

1、To achieve fast high frequency turn-on and off circuit, an unlimited number of switching times

2、No noise was made during turning on/off, no spark, and no electromagnetic interference

3、Compared to normal electromagnetic relay modules, it has a longer service life

4、Dual-MOS in parallel active output, lower inner resistance, larger current, strong power; at room temperature, operating current is up to 15A, power up to 400W, that can be used for most equipment

5、Wide voltage input from 5V to 36V, normally used for controlling DC motors, lights, LED strips, micro-pumps, solenoid valves, etc., very convenient

Features:

To achieve fast high frequency turn-on and

off circuit, an unlimited number of switching times.

No noise was made during turning on/off, no

spark, and no electromagnetic interference.

Compared to normal electromagnetic relay

modules, it has a longer service life.

Dual-MOS in parallel active output, lower inner

resistance, larger current, strong power; at room temperature, operating

current is up to 15A, power up to 400W, that can be used for most equipment.

Wide voltage input from 5V to 36V, normally

used for controlling DC motors, lights, LED strips, micro-pumps, solenoid

valves, etc., very convenient.

It has an emergency stop function ("STOP" button)

and reverse input protection.

Automatically enter sleep mode and shut off

display if no operation in 5 minutes, and will be wake up by pressing any

button.

You can set different OP, CL, LOP

parameters, which are independent of each other, and are saved separately;

All parameter settings will be saved

automatically if there is a power failure.

Specifications:

Voltage: DC 5V~36V.

Trigger Signal Source: High voltage level

trigger (3.0V~24V), signal ground and system ground are not on common ground to

improve the system's anti-jamming capability (you can also connect them on

common ground).

Output Capacity: DC 5V~36V, at room

temperature, continuous current is 15A, power 400W. With enhanced heat

dissipation, the current can be up to 30A.

Quiescent Current: 20mA

Operating Current:

50mA

Working Temperature: -40℃~85℃

Clocking (Time Delay) Range: 0.1seconds to

999minutes

Size: 60*34*12mm / 2.36*1.33*0.47"

Instruction:

Operating Mode:

P1: trigger signal, the relay is on

"OP" time, and then disconnect; in the "OP" time, as

follows:

P1.1: signal is triggered again, invalid

P1.2: signal is triggered again, the clocking

is reset

P1.3: Signal is trigger again reset, relay

off, and stop the clocking;

P-2: trigger signal, the relay off

"CL" of time, the relay on "OP" time, and then disconnect

relay after clocking;

P3.1: trigger signal, the relay is turned

on after the "OP" time, the relay off "CL" time, then the

operation cycles; if trigger signal again during the cycle, the relay off, stop

clocking; the number of cycles times ( "LOP ") can be set.

P3.2: without triggering signal after power

on, the relay is on "OP" time, the relay off "CL" time, then

the operation cycles; the number of cycles times ( "LOP ") can be

set.

P-4: signal holding function. If there is trigger

signal, clocking is reset, the relay remains on; when the signal disappears,

after clocking "OP" time, the relay is off; if another signal is

triggered during clocking, clocking will be reset.

How to Set Clocking Range:

After setting the parameter value at mode

selection, press "STOP" button to set the clocking range;

XXX. The last decimal point lights up,

range: 1 second to 999 seconds.

XX. X The second last decimal point lights

up, range: 0.1 seconds to 99.9 seconds

X. X. X. all 3 decimal points light up,

range: 1 minute to 999 minutes.

For example, if you want to set

"OP" as 3.2 seconds, light up the second last decimal point, and set

digit display as 03.2

Parameter Description:"OP" - on

time, "CL" - off time, "LOP" - number of cycle times (1-999

times, "---" represents infinite loop).

These parameters are independent of each other,

but are shared by each mode. For example, in P1.1 mode, set the on-time

"OP" is 5 seconds, if you switch to P1.2 mode, its "OP"

will also be 5 seconds.

In the main interface (display 000), press

"SET" button will display "OP" ( "CL",

"LOP") and the corresponding time XXX;

If the mode (such as the mode P1.1, P1.2,

P1.3) only has "OP" time, press the "SET" key to display

only the "OP" and the corresponding time;

Some models (such as the mode P3.1, P3.2)

have parameters "OP", "CL", "LOP", press

"SET" button will display "OP" and the corresponding time, "CL" and the corresponding time, "LOP" and the corresponding number of times;

After setting mode, in the main interface press

"SET" key to see information about the parameters of the current

mode, very convenient.

How to Set Parameters:

1. First, read the instructions to

determine the required operating mode.

2. The module is powered up, the display at

the current work mode (P1.1 default mode), then enter the main interface; press

and hold "SET" button for 2 seconds to enter mode selection

interface; then press "UP", "DOWN" button to select the

mode (P1.1 ~ P-4).

3. Select the mode (such as P3.2), then

press the "SET" button, the parameter to be set flashes (

"OP" on-time, "CL" off time, "LOP" cycles (

"---" represents infinite loop)), press(or press and hold)

"UP", "DOWN" button to adjust the parameter value; then

press the "STOP" key to set the decimal point position to select the clocking

range (0.1 seconds to 999 minutes); press the "SET" button to set the

next parameters of the current mode, method is same as above.

4. After the parameters are set, press and

hold "SET" button for 2 seconds, then the current mode will flash

once, and then return to the main interface, which means the parameters are successfully

set.

The main interface: If the relay is not in work state, it

display "000" with no decimal point), if it is in work state, it has decimal

point.

Mode selection screen: Press and hold the

"SET" button to enter; after setting, press and hold the

"SET" button to exit back to the main interface.

Relays Enable Mode:

1. ON: Relay allows conduction in the

"OP" on-time;

2. OFF: Relay prohibits conduction and is

always closed;

In the main interface, press the

"STOP" button to switch between ON and OFF, the current state will

flash, and then return to the main interface. (This feature is an emergency

stop function, press on button to disconnect relay)

Sleep Mode:

1. "C-P" Sleep mode: five minutes

without any operation, the digital display automatically turns off, the program

running as usual;

2. "O-d" Normal mode: digital

display turns on always;

Press hand hold the "STOP" button

for two seconds to switch "C-P" and "O-d" state, the

current state flashes and then return to the main interface.

Note:

1. The module is an active output, the

output voltage equal to the input voltage.

2.'DC + 'and' load + ' are internally shorted(connected), but' DC- 'and' load - ' cannot be

shorted, otherwise the load cannot be controlled on and off, which is

equivalent to load being powered on always.

Package Includes:

1 xTimerSwitchModule

Features

  • Brand
    STUNACY
  • ManoMano Reference
    ME215566413
  • MMID
    940827653008
  • Product code
    STYM0512-GS01406
  • EAN
    4970488578260
You are here:
The DIY, home and garden specialist

The DIY, home and garden specialist

Reliable delivery

Reliable delivery

Payment in 3x or up to 30 days free of charge

Payment in 3x or up to 30 days free of charge

More than 7 million individual and professional customers

More than 7 million individual and professional customers