Skip to main content
1/5

RCBO Residual Current Circuit Breaker 1P+N C63A 6kA Type C

(£5.76/pcs)

You may also like

3P+N 16A C curve RCBO 6kA EN61009

3P+N 16A C curve RCBO 6kA EN61009

(£14.96/pc)
Free shipping
2P 40A C Curve 6kA Residual Current Circuit Breaker EN61009
#1 in sales

2P 40A C Curve 6kA Residual Current Circuit Breaker EN61009

(£9.48/pc)
Free shipping

Compare with similar items

Product information

Description

1) All-in-one combined protection (RCBO) for single-phase circuitsThis 1P+N miniature residual current circuit breaker, C curve, 63 A combines, in a single module, protection against overloads and short circuits as well as residual current protection against insulation faults (current leakage). It is designed to effectively secure standard electrical installations (homes, shops, offices, small workshops) where a single device is required that can react quickly in the event of abnormal conductor overheating, a solid short circuit or leakage to earth (damaged cable, moisture, faulty appliance, indirect contact on a metal mass). By cutting off the power supply as soon as a fault is detected, it helps reduce the risks of electrically caused fire, material damage to equipment and the risk of electrocution.2) 1P+N format: phase disconnection and neutral isolation for safer maintenanceThe 1P+N configuration is particularly suited to single-phase circuits: the device provides protection on the phase and isolates the neutral in an associated manner during operation. This architecture is valued in domestic and commercial distribution boards, as it improves day-to-day ease of use: during troubleshooting, equipment replacement or inspection, switching off the power is clearer and more reassuring (while still remembering that any work must remain in accordance with good practice and ideally be carried out by a qualified person). This choice also meets European practices where a clear circuit disconnection is preferred, particularly in mixed environments (sockets, small motors, household appliances, technical auxiliaries).3) 63 A rating: for main incomers or high-power outgoing circuits, with broad network compatibilityWith a rated current of 63 A, this model is more intended for a main supply or a high-power outgoing circuit (depending on the design of the distribution board, the conductor cross-section and the actual power drawn). It is rated for use in AC 230–400 V and accepts 50/60 Hz networks, making it compatible with the majority of low-voltage installations found in Europe. For an appropriate choice, it is essential to match the rating to the cable cross-section and the permissible current of the line: a rating that is too high may delay cable protection, while a rating that is too low may cause nuisance tripping. This balance is a key point in maintaining both safety and continuity of service.4) C tripping curve: greater stability with inrush current loadsThe C curve is recommended when the circuit supplies loads that may present a start-up current (inrush): small motors, pumps, fans, low-power compressors, switched-mode power supplies, transformers, certain professional equipment or household appliances. It helps avoid unnecessary tripping when switching on while maintaining a reliable response in the event of a genuine overload or short circuit. It is a popular compromise in modern distribution boards, where resistive appliances (heating) coexist with power electronics equipment, often sensitive to micro power cuts but liable to generate current peaks at start-up.5) EN 61009 compliance and 6 kA breaking capacity: safety and fault withstand in residential/commercial environmentsCompliant with EN 61009 (requirements applicable to residual current circuit breakers with overcurrent protection), this device fits within the Euro-compatible practices expected on the French and European market for combined protection devices. Its 6 kA breaking capacity meets the short-circuit levels frequently encountered in domestic and small commercial installations, ensuring safe disconnection during a major fault. For a reliable installation, it is advisable to respect phase/neutral wiring, terminal tightening torque, DIN rail mounting and periodic verification of correct operation according to the applicable safety procedures. Thus, this miniature residual current circuit breaker constitutes a robust solution for strengthening the protection of people and property in a modern electrical distribution board.

Features

  • Brand
    OTHERS
  • Tripping curve
    C
  • IP rating
    IP20
  • Nominal intensity
    AC
  • Material
    Plastic
  • Breaking capacity
    6 kA
  • Electrical network
    Single-phase
  • Sensitivity type
    AC
  • ManoMano Reference
    ME222479566
  • MMID
    152198355592
  • Product code
    LXCMANOIT-00903
  • EAN
    5901447855893