YYB-5 12v 24v Forward/Reverse Motor Control Board Dual Relay Delay Synchronization Cycle Module
Buying for your business?
Negotiated prices excl. VAT up to -20%
You may also like
Compare with similar items
Product information
Description
1. 100% brand new and high quality 2. 6 commonly used functions to meet the needs of more applications; 3. It can control 2-way solenoid valves, pumps, motors, lights, and other freely operating devices 4. Output power: It can control a 30A DC or AC load 5. Time range: 0.1 seconds to 999 minutes, adjustable at any time
Specification:
Features: 100% brand new and high quality 6 commonly used functions to meet the needs of more applications; It can control 2-way solenoid valves, pumps, motors, lights, and other freely operating devices. Output power: It can control a load within 30A DC or AC. Time range: 0.1 seconds to 999 minutes, adjustable at any time. Specification: Model: YYB-5 Input voltage: DC/AC 7V~27V Time range: 0.1 seconds to 999 minutes Weight: Approximately 103g/3.6oz
Wiring port description: 1. AC/DC: Input 7V~27V 3. IN1: Signal input 1 (negative trigger) 4. IN2: Signal input terminal 2 (negative trigger) 2. IN3: Signal input 3 (negative trigger) 5. NO: Relay normally open interface; the relay is pulled before suspension and shorted after connection to the COM port. 6. COM: Relay common interface 7. NC: Relay normally closed interface; the relay is pulled before connection to the COM port and shorted after suspension. the suspension
List of functions: P - 1: to signal 1, relay 1 pulls towards A, the time stops automatically; to signal 2, relay 2 pulls towards B, the time stops automatically; signal 3 is the emergency stop reset signal. P - 2: signal 1, relay 1 is pulled towards A, the time stops automatically; relay 2 signals to start the delay B, after the pull-up to time C, stops automatically (this function time unit must be consistent). P - 3: After power-up, relay 1 pulls up to time A, while waiting for time C, relay 2 pulls up to time B, waits for time C; Relay 1, 2 turns endless operation endless cycle (If the control motor is reversible, this can be understood as: the motor runs for a certain time; stops for a certain time; automatically reverses for a certain time; stops for a certain time; then automatically advances; P - 4: to signal 1, relay 1 pulls; to signal 2 (limit), relay 1 stops and starts counting up to A. Timer relay 2 pulls; at signal 3 (limit), relay 2 stops and starts the timer. For B, timer relay 1 pulls; infinite loop (If the control motor is reversible, this can be understood as: press start button 1; the motor moves to limit 2 to stop for a period of time; automatically reverses at limit 3 to stop for a period of time; then automatically advances; P - 5: to signal 1, relay 1 pulls; to signal 2 (limit), relay 1 stops and starts To time A, pull relay 2; give signal 3 (limit), relay 2 stops; Signal 1; again (If the control motor is reversible, this can be understood as: press start button 1; the motor moves to limit 2 to stop for a period of time; automatically reverses to limit 3 to stop; give signal 1; P-6: to signal 1, pull relay 1; at signal 2 (limit), relay 1 stops; give signal 1, pull relay 2; at signal 3 (limit), relay 2 stops; (If the control motor is reversible, this can be understood as: press start button 1; go to limit 2; press start button 1 again; reverse to limit 3; If the remote control function: remote control key A and key B to start the above function; Key C press relay 1 to work (forward); then press relay 1 to stop (stop); Press D to activate relay 2 (reverse); Press relay 2 once to stop (stop);
Key parameter description: Displays power "----" which enters standby mode; Press K1 once, the screen displays: P-1: Setting mode K2 and K3 Press K1 a second time, the screen displays: A001: K2 and K3 adjust A for the first time, K4 adjusts the decimal point (time unit) Press K1 a third time, the screen displays: B001: K2 and K3 adjust B for the second time, K4 adjusts the decimal point (time unit) Press K1 a fourth time, the screen displays: C001: K2 and K3 adjust C for the third time, K4 adjusts the decimal point (time unit) Press K1 a fifth time, displays "----" which has entered standby mode; For example; Mode setting required: P - 2; Time: A010 B005 C006: indicating the second operating mode; after signal 1; relay 1 activates after 10 seconds to start; relay 2 activates after a 5-second delay after starting; automatically shuts off after 1 second. Decimal Time Unit Description: XX.X decimal point in tens, time range: 0.1 seconds to 99.9 seconds; XXX without decimal point, time range: 1 second to 999 seconds; XXX with decimal points in a single time range: 1 minute to 999 minutes. Package List: 1 x Motor Control Board
Note: Please be aware that the new and old types of this product will be sent randomly, and please ensure this is acceptable before ordering.
Features
- BrandOTHERS
- ManoMano ReferenceME223230758
- MMID788619427962
- Product codeKrlin-25638