Electronic pH Meter, 5-in-1 Pool Water Tester with Backlight, pH/TDS/EC/Salinity/Temperature with ATC, High Precision pH Meter with 0.01 Resolution, for Drinking Water, Aquarium, Spas
You may also like
Compare with similar items
Product information
Description
【5-in-1 Function】This is a water testing kit with a pH tester, TDS meter, and EC/salinity temperature tester. The backlit LCD screen makes it easy to read the displayed values.
【Easy to Use】Press the power button to turn on. Press "HOLD" to lock the value, press and hold "HOLD" to change the temperature unit. Press "MODE" to switch between the different functions.
【Absolute Accuracy】PH resolution: 0.01 pH, accuracy ±0.05 pH. TDS meter resolution: 1 ppm 0.1 ppt, accuracy ±2%. Conductivity resolution: 1 µS/cm 0.1 mS/cm, accuracy ±2%. Thermometer resolution: 0.1°C/°F, accuracy ±0.5°C. Salinity resolution: 0.01%, accuracy 0.01-5.00% (±0.1%) 5.10-25.00% (±1%)
【Wide Application】Ideal for home or laboratory use. Suitable for testing the pH balance of drinking water, swimming pools, aquariums, RO systems, spas, or hydroponic systems
【Robust and Durable】This pool tester is IP67 waterproof, so it can continue to be used even if it falls into the aquarium. If the electrode is placed for a long time and is exposed to air, the readings will be slow and unstable due to the electrode drying out. You must immerse the electrode in water for a few hours and recalibrate the device before use.
What's in the package:
5-in-1 Water Quality Tester
PH4.00 Calibration Powder
PH6.86 Calibration Powder
PH9.00 Calibration Powder
Operating Instructions
Features:
Automatic Calibration
Backlit LCD Screen
IP67 Waterproof
Automatic Shut-Off
Easy to Use
Lock the Value/Temperature Switch
Press the "ON" button to turn on, press the "HOLD/TEMP" button to lock the value, and press and hold "HOLD/TEMP" to change the temperature unit.
Using the Mode Switch
Press the "ON" button to turn on, touch "MODE/CAL" to switch between modes.
Quick and Accurate Calibration of pH Meters
1. Before calibration, add the pH4.00/pH6.86/pH9.18 buffer powder to a container with 250 ml of distilled water and stir until the powder is completely dissolved.
2. Press the "ON/OFF" button to turn on the pH meter and switch to pH mode.
3. Place the electrode in the standard pH6.86 solution and wait for the reading to stabilize (usually 5 to 10 seconds).
4. Press and hold the MODE/CAL button for 6 seconds and release it until the pH6.86 reading stops flashing and the pH6.86 calibration is complete.
5. Repeat the steps above to complete the pH 4.00/pH 9.18 calibration in order.
NOTE: Always strictly follow the pH 6.86, pH 4.00, pH 9.18 calibration sequence. Otherwise, the calibration result will be inaccurate.
For more operation videos, please visit the link https://files.fm/u/e2w326wwvg
Features
- BrandSNQ
- Weight200 g
- MaterialPolystyrene (PS)
- IP ratingIP67
- Power sourceBatteries


















