Skip to main content
1/5

Ammeter, structure solid elegant for the outdoor

£36.84

Buying for your business?

Negotiated prices excl. VAT up to -20%

Sold by HERSAMA

You may also like

Sealey Pocket Multimeter MM18SEALEY

Sealey Pocket Multimeter MM18

Free shipping

Compare with similar items

Product information

Description

Features:

1. The head of meter is a design current, it is-to-say. e. the wire of ground side measured is relie at the wire of ground side power supply (except the mesureur of insulation).2. The head of meter is equipped of a potentiometre of calibration of voltage, of a potentiometre of calibration of current, it there has a error, you can l'etalonner, because the error is absolue.3. The voltmeter uses the design of the movement automatic of the point decimal.4. This meter has a strong capacity anti-interference and a rate of rafraichissement of display fast.5. The head of meter used a wide range of power supply : DC3.5 ~ 30V (except the meter of insulation), the connection inverse of the power supply will burn not.Specifications:Features&xa0:The head of the meter is a design current, it is-to-say. e. the wire of ground to the end of measured is relie at the wire of ground to the end of power supply (except the meter of insulation). The head of the meter is equipped of a potentiometre of calibration of voltage and of a potentiometre of calibration of current. it there has a error, you can the calibrated, because the error is absolue. The voltmeter uses the design of the movement automatic of the point decimal. This meter has a strong capacity anti-interference and a rate of rafraichissement of display fast. The head of the meter used a wide range of power supply : DC3,5 ~ 30 V (except the meter of insulation), the connection reversed of the power supply will burn not. The head of the meter is equipped of five cables, the connection is practical, it is used for monitoring the voltage of the battery, for grip the condition of voltage of the battery in the time and for measured the voltage and the current of other products. Specification&xa0:Range of measured of voltage 0 ~ 99,9 VResolution 0,01 V (Range of measured of amperes0-9,99-20 AResolution 0,01 Has (10 Has)Rate of measured ≥ 500 mS/times br>Precision of measured 1&xa0% (± 1 mot)Supply Voltage minimum+3,5 VSupply Voltage maximum+ 30 VOperating Temperature-10 ~ + 65Moisture of operation10 ~ 80 % (without condensation)Pressure of travail80 ~ 106 kPaExposition to the light of the soleilpas of exposure directeRemarque&xa0:Supply Voltage (meter without insulation)&xa0: DC3,5 ~ 30&xa0V (wide range), note&xa0: the voltage of input maximum must not exceed 30&xa0V , otherwise it there has risk of brulureLa head of shown of 20Has _ shunt integreEtant data that a battery 24V can have a voltage flottante of more than 30V after its filling, it is recommended that the power supply \"non\" directly with batteries 24VDans the case following, it is strongly recommended that : a meter of insulation (meter of power supply of insulation)When two meter or more are installed in a devices, they cannot be only, independent or insulation when the power supply is fournieMethode of connection&xa0:This meter is equipped of five line, please find of professional strictly according to the schema of wiring following, if you avez of questions, hesitate not to contact the service client&xa0:Power of the head of the meter power supply&xa0: socket to two filsLigne fine _ black&xa0: power supply of the head of the compteurLigne fine _ red&xa0: the power supply of the head of shown is positive (attention, the voltage between the fine line red and black cannot exceed 30&xa0V) Meter of insulation (power supply insulated)&xa0: the end of power supply of the head of the meter and the end of test are completely insulation and insulation the a of the other, can partager a source of power supply on several meters, \"not need\" worry of all output of problems of interference caused by the partage of l'Power Supply, suitable at the banc of test of aging in machined, at the banc of test or to all other equipment requiring more of a meter of teteSupply Voltage&xa0: DC8-18VFin of the test&xa0:COM&xa0: Tested the end communeV +&xa0: tested the input of voltage positiveA +&xa0: tested the end of input of current \"positive\"&xa0; Because that the head of the meter uses the design of masse commune, it is-to-say that the wire of ground to the end of measured is connected with the wire of ground to the end of the power supply, of output that it can be connected that between the power supply negative and negative of the equipment tested, as the shown the figure following, the error of connection will burn (if only the voltmeter is used, it It is recommended of connect the line yellow to the line black, to prevent the flicker digital of the ammeter caused by of interference external)Method of connection without shunt&xa0: fits \"in below of 20Has\" without connection external.

Features

  • Brand
    BEIJIYI
  • Display mode
    Digital
  • ManoMano Reference
    ME244969022
  • MMID
    172303271471
  • Product code
    GB01734
  • EAN
    9306497126195
You are here:
The DIY, home and garden specialist

The DIY, home and garden specialist

Reliable delivery

Reliable delivery

Flexible payment options

Flexible payment options

More than 7 million individual and professional customers

More than 7 million individual and professional customers